Dual-frequency negative-pressure amplitude and cavitation threshold
For the studied setup the cavitation threshold is 0.10387 MPa, and dual-frequency excitation often produces negative-pressure amplitudes clustered around ~0.18 MPa, which is more conducive to cavitation than typical single-frequency amplitude (~0.13 MPa) under comparable energy input .
The influence of phase difference on the negative-pressure amplitude is significant for harmonic ratios, and the optimal phase difference for maximizing negative pressure follows a periodic pattern across frequency ratios .
Bubble radius time-evolution and phase-dependent onset of expansion–contraction
Dual-frequency coupling leads to more complex, often transient bubble dynamics: initial tiny oscillations are followed (when negative pressure exceeds threshold) by one or a few pronounced expansion–contraction cycles; the timing of onset depends on the phase difference .
The phase ordering that triggers expansion–contraction cycles varies with frequency ratio and cycles periodically as 1.5π → π → 0.5π → 0 → 1.5π across the studied α values, enabling potential phase-based micromanipulation control of cavitation .
Maxima of cavitation parameters vs. frequency ratio; ultraharmonics produce more stable behavior
The maxima of bubble radius, internal pressure, energy, and number of water vapor molecules all exhibit a spiral-like decline as frequency ratio α increases, implying cavitation intensity decreases with higher α (e.g., maximum bubble radius falls from ~80 μm at low α to ~30–40 μm at large α) .
For harmonics (α = 2,3,4,5...), the phase difference significantly affects the maximum cavitation metrics; for ultraharmonics (α = 1.5, 2.5, 3.5, 4.5...), the maxima cluster tightly across phase differences, indicating ultraharmonics are less sensitive to phase jitter and therefore facilitate more stable cavitation .
Practical implication: if phase control is limited, using ultraharmonic combinations can yield reproducible cavitation effects; if maximizing peak negative pressure is desired, select harmonic frequency ratios with the phase difference identified as optimal in Fig.1 .
思维导图
深度阅读
报告元数据与概览
报告标题:Effect of frequency ratio and phase difference on the dynamic behavior of a cavitation bubble induced by dual-frequency ultrasound;作者:Linzheng Ye, Xijing Zhu, Yan He, Tianjiao Song;单位:North University of China 等机构信息均列出在文首与 Acknowledgments 中。,
主题与关键词:研究双频超声(dual-frequency ultrasonic)中频率比(α)与相位差(φ)对空化泡动态行为(包括泡半径、泡内压力、能量及水蒸气分子数)的影响,关键词明确为“Dual-frequency ultrasonic, Cavitation dynamics, Frequency ratio, Phase difference”。
能量归一化:为保证与单频可比,作者设定双频两分量各自幅值 P(相同),并使总能量与单频 Pa 相等,从而 P = Pa/√2,例如 Pa = 0.13 MPa 时双频每分量幅值 P = 0.0919 MPa,此设定用于后续比较。该能量归一化假设会影响双频与单频比较结果的直接性,应作为后续批判讨论的依据之一。